Coenzyme Q10, Total Q10TOT

Method(s) Quantitative High Performance Liquid Chromatography
Specimen Required
Collect

Plasma separator tube, green (sodium or lithium heparin) top tube, serum separator tube, or plain red top tube.

Transport

1 mL serum or plasma to an amber vial (Min: 0.3 mL).

Remarks

Separate plasma or serum from cells within 1 hour of collection.

Stability

After separation from cells: Ambient: Unacceptable; Refrigerated: 3 weeks; Frozen: 1 month.

Unacceptable Conditions

Specimens other than heparinized plasma or serum. Hemolyzed specimens. Specimens exposed to repeated freeze/thaw cycles.

Schedule Tues, Thu, Sat
Billing Code 5011670
CPTCode 82491
Preferred Specimen Collection Device(s)
Reference Interval

0.4-1.6 mg/L

No Appointment Necessary